Workflow Node Reference

Output Nodes Reference

Every output node that sends workflow data somewhere, email, SMS, APIs, FTP, and more.

These are the nodes under the Workflow editor's Output Connectors palette (see Connector Nodes Reference for input/control/logic nodes). They all sit at the end of a workflow branch, connect an upstream node's output into one of these to actually send or deliver the data somewhere.

Output to Email NodeOutput

Sends the payload data from a workflow as an email at a specific point in the flow. Use it for real-time alerts, scheduled reports, fault routing, or compliance logs.

How to configure it:

  1. Set the required Node Name.
  2. Optionally enable "Enable for event-based report" (off by default).
  3. Under Email Fields, enter the required Subject and required Body (both support dynamic variables), and optionally a Header and/or Footer.
  4. Under Sender, optionally set a Sender Name.
  5. Under Recipients, choose one or more: toggle "Configure recipients in User Group" (off by default) to pick a predefined Rayven user group; enter comma-separated addresses under "Send to email (without creating user)"; or pull recipients dynamically from the payload with "JSON key with emails".
Good to know: No mail server setup or domain verification is required, but at least one recipient method must be configured or the node logs an error. Attachments aren't supported, use a File Output node or cloud storage instead. Only basic HTML formatting is supported.
Output to SMS NodeOutput

Sends an automated SMS from a workflow.

How to configure it:

  1. Optionally add a Header.
  2. Enter the required Body (can include payload values).
  3. Optionally add a Footer.
  4. Toggle "Configure recipients in User Group" (off by default), enter a number under "Send to mobile number (without creating user)", or pull one dynamically with "JSON key with mobile numbers".
  5. Optionally set a Sender Name.
Good to know: Always include country codes (e.g. +61 for Australia). Keeping messages under 160 characters is recommended. Delivery depends on external SMS gateways/networks and isn't guaranteed by the workflow.
API NodeOutput

Sends outbound HTTP requests from a workflow to an external API, an HTTP client that can push data and optionally parse the response back.

How to configure it:

  1. Drag it from the Connectors panel and link an upstream data source.
  2. Set the required Node Name, required API Endpoint, required HTTP Method (GET/POST/PATCH/PUT/DELETE), and required Payload Format (JSON).
  3. Under Advanced Features, optionally set an API Bearer Token, an Output JSON Key, and a Body (for POST or PATCH), or toggle Use incoming payload as body in POST request or Use URL encoded form (both off by default), adding URL-encoded key/value Pairs as needed.
  4. Under Headers, add Key/Value pairs; under Cookies, add Name/Value pairs.
  5. Under Payload Date Settings, optionally set the Timestamp JSON Key, Timestamp Format (e.g. yyyy-MM-dd HH:mm:ss), and Time Zone.
  6. Under Authentication, optionally set a Username/Password, and toggle Digest Authentication or Ignore Invalid SSL Certificates (both off by default; enable SSL bypass only for self-signed certificates).
Good to know: You'll need a valid, reachable API endpoint URL, the correct HTTP method, and any required credentials.
Overlap with another node: This overlaps heavily with the Pull Data Node on the Connector Nodes reference page, both make outbound HTTP calls. The API Node additionally supports PUT/DELETE methods and an "Ignore Invalid SSL Certs" option; Pull Data supports PATCH and Digest Auth. Either works for a straightforward outbound call.
Output to FTP NodeOutput

Uploads workflow data to a remote FTP server as delimited (CSV-style) rows on a schedule. Useful for legacy system integration and file-based ETL.

How to configure it:

  1. Drag it onto the canvas and connect an upstream data source.
  2. Set the required Node Name, and choose the FTP Transfer Mode (e.g. Batch to FTP on schedule).
  3. Enter the required FTP Address, required Username, and required Password; optionally enable Enable TLS for secure FTPS.
  4. Set the required Delimiter character, the required Upload Interval, and the required Interval Units.
  5. Optionally toggle Add Header Row.
  6. Map each field with a required Incoming JSON Key and required Output Column Name, adding more with + Add Case.
  7. Optionally set a Filename JSON Key, File Contents JSON Key, or toggle Write Base 64 to File.
  8. Under Activation, optionally select a Filter (like PrimaryLabel=All) to tie the data to.
  9. Click Activate to enable it, then Apply Changes to save.
Good to know: You'll need write access to the target FTP server. Uploaded files use timestamp-based filenames and are never overwritten, each cycle appends a new file. Only delimited row-based output is supported, not XML/JSON export.
Output to MQTT NodeOutput

Publishes workflow data to an MQTT broker topic.

How to configure it:

  1. Set the required Node Name.
  2. Set the required Broker Address (defaults to broker.rayven.io), and optionally a Broker Port (default 1883) and Client ID.
  3. Provide the required Username and an optional Password.
  4. Set the required MQTT Topic (e.g. my_topic/[[device_id]]).
Good to know: Use [[device_id]] in the topic to publish per-device data to distinct subtopics.
Modbus Output NodeOutput

Writes data to a Modbus device, sending values to coil or holding register addresses on a PLC.

How to configure it:

  1. Drag it from the Outputs section.
  2. Under General, enter the Node Name.
  3. Enter the Address (destination IP of the Modbus device).
  4. Enter the Port (default 502).
  5. Enter the Field Name (reference label).
  6. Set the Outputs type: Coil Outputs (writable, boolean) or Register Outputs (writable holding registers, ushort).
  7. Enter the Modbus field Address (e.g. 40001–49999).
  8. Enter the Value (the JSON field providing data to write).
  9. Click Activate, then Save.
Good to know: Target addresses must be writable, coils and holding registers are read-write, but discrete inputs and input registers are read-only and can't be used here. Values must be transformed to fit 1 bit (coils) or 16 bits (holding registers); larger values may need splitting across multiple addresses.
Overlap with another node: This is the write counterpart to the (read-only) Modbus input node on the Connector Nodes reference page.
FTP NodeInput (despite the name)

Despite living in the Output Connectors palette, this node is actually input-only, it pulls files IN, it doesn't send them out. It's fully documented on the Connector Nodes reference page alongside the other input/source nodes.

This node only brings files into a workflow, it can't send files out. To send files OUT to an FTP/SFTP server, use the Output to FTP Node above instead.
Send Data To NodeOutput

Forwards the current workflow payload as-is to a specific node in a different workflow, unmodified, enabling cross-workflow communication and modular, reusable workflows.

How to configure it:

  1. Drag it onto the canvas.
  2. Give it a descriptive, required Node Name.
  3. Enter the required Destination Workflow ID (found in that workflow's settings/URL).
  4. Enter the required Destination Node ID (the specific node in the destination workflow).
Good to know: The destination workflow must be active/published and built to accept the incoming payload structure, since data passes through unmodified. Each node instance targets only one destination. As a best practice, keep a documented mapping of workflow/node IDs.
Overlap with another node: Each Send Data To node instance can target only one workflow ID and one node ID, use multiple instances if you need to forward to multiple destinations.
Mailchimp Connector NodeOutput

Sends transactional emails through Mailchimp from a workflow, order confirmations, password resets, immediate personalized notifications.

How to configure it:

  1. Drag the Mailchimp output node onto the canvas.
  2. Set the Recipient Email Address.
  3. Set the Subject Line.
  4. Set the Message Body (static or dynamic content with placeholders for personalization).
  5. Connect the node to the trigger that should fire it.
  6. Test the node to confirm the API key works and a sample email sends.
Good to know: You'll need an active Mailchimp account and an API key from Mailchimp's Account Settings → Extras → API Keys, added to Rayven under Settings → Credentials.
Overlap with another node: For Mailchimp functionality beyond transactional email (e.g. audience/list management), use an HTTP Node to call the Mailchimp API directly instead.
Output to HTTP (Webhook) NodeOutput

Sends the received payload as an HTTP POST request to a specified external URL whenever it receives one, used to trigger external systems or integrations.

How to configure it:

  1. Drag it from the Connectors panel and connect upstream node(s).
  2. Enter the required Node Name.
  3. Enter the Destination (POST) Endpoint (the target URL).
  4. Set the Output Format (JSON, XML, or String).
Good to know: The destination must accept POST requests in the chosen Output Format and should be confirmed reachable, always use HTTPS. There's no built-in custom auth headers or retry logic; delivery is best-effort with no response validation.
Overlap with another node: This is simpler than the API Node (POST-only, no auth/headers), use the API Node if you need other HTTP methods, authentication, or custom headers.
Output to API (GET Endpoint) NodeOutput

Exposes workflow data through a device-specific, authenticated HTTP GET endpoint that external systems can poll, the workflow doesn't call out, it publishes an endpoint instead. Returns the most recent values for a device UID as flat JSON/XML/CSV.

How to configure it:

  1. Drag it onto the canvas from the Connectors panel.
  2. Set the required Node Name.
  3. Optionally choose an Authentication method (default None) and, if required, a Username and Password.
  4. Note the auto-populated, required API Endpoint URL (format https://iotx1.rayven.io:8082/api/apipull?uid=...).
  5. Optionally set an IP-based restriction (multiple addresses with subnet mask).
  6. Optionally enable Pass Data as Received.
  7. Choose the required Outbound Format (JSON, XML, or CSV).
  8. Build output columns: a required JSON Key, required Display Name, and required Field Type (e.g. UID, Timestamp, JSON Key); click + Add Column for more.
  9. Click Apply Changes to save.
Good to know: You'll need a workflow with a device/UID already sending data in. There's no caching/refresh setting, it always reflects the latest data for that UID.

Frequently Asked Questions

Why is the FTP Node on the Output Nodes page if it doesn't send anything out?

It's grouped in the Output Connectors palette for historical/UI reasons, but the FTP Node is actually input-only, it pulls files in from an FTP/SFTP server. Its full configuration steps live on the Connector Nodes reference page alongside the other input nodes. To send files out, use the Output to FTP Node instead, also on this page.

What's the difference between the API Node and Output to HTTP (Webhook) Node?

Output to HTTP (Webhook) is simpler: POST-only, JSON/XML/String output, no authentication or custom headers. The API Node supports GET/POST/PATCH/PUT/DELETE, custom headers, and Bearer/Basic/Digest authentication. Use the webhook node for a quick fire-and-forget POST, and the API Node when you need auth or a different HTTP method.

Does Output to API (GET Endpoint) send data anywhere, like the API Node does?

No, this one works in reverse. It publishes a GET-able URL that external systems poll for a device's latest data, your workflow never calls out. The API Node, by contrast, actively sends outbound requests. Don't confuse the two just because both have "API" in the name.

Can I attach a file to an Output to Email Node?

No, attachments aren't supported on the Output to Email Node. Use an Output to FTP Node or cloud storage to deliver files instead, and reference the file's location in the email body if needed.

Why does my Modbus Output Node fail to write a value?

The target address is probably read-only. Only Coil Outputs and Holding Registers accept writes, discrete inputs and input registers can't be written to. Also confirm the value fits the address's bit width (1 bit for coils, 16 bits for holding registers).

Which node publishes workflow data to an MQTT topic?

Output to MQTT, on this page, publishes to a broker topic. It's the write counterpart to the read-only MQTT node on the Connector Nodes reference page.

How do I write a Workflow's output into a Table instead of sending it externally?

Use an Update Tables node (upsert), see the Logic Nodes Reference and Tables for how it writes into a Table.

Where do I find the input-side connector nodes, not outputs?

See the Connector Nodes Reference for every node that brings data into a workflow or captures dashboard input.

Where do I find nodes for transforming data before it reaches one of these outputs?

See the Logic Nodes Reference for the transform, filter, and aggregation nodes that typically run before an output node.